{"id":19374671,"date":"2024-12-12T14:00:25","date_gmt":"2024-12-12T13:00:25","guid":{"rendered":"https:\/\/www.metrologicdcs.com\/metrolog-et-silma-x4-x4v5-v22ga-release\/"},"modified":"2024-12-12T14:00:25","modified_gmt":"2024-12-12T13:00:25","slug":"metrolog-et-silma-x4-x4v5-v22ga-release","status":"publish","type":"post","link":"https:\/\/www.metrologicdcs.com\/fr\/metrolog-et-silma-x4-x4v5-v22ga-release\/","title":{"rendered":"Metrolog et Silma X4-X4V5 V22GA Release"},"content":{"rendered":"<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-19367206\" src=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/Release-V22-EN.png\" alt=\"\" width=\"884\" height=\"544\" srcset=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/Release-V22-EN.png 1040w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/Release-V22-EN-600x369.png 600w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/Release-V22-EN-1024x630.png 1024w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/Release-V22-EN-400x246.png 400w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/Release-V22-EN-768x473.png 768w\" sizes=\"(max-width: 884px) 100vw, 884px\" \/><\/p>\n<p>Nous avons le plaisir de vous annoncer la sortie de votre nouvelle version X4 Product Line <strong>V22GA<\/strong>. Cette version est d\u00e9j\u00e0 disponible sur votre Extranet : <\/p>\n<p><a href=\"https:\/\/extranet.metrologic.group\/Products\" rel=\"nofollow noopener\" target=\"_blank\">Acc\u00e9der \u00e0 la zone de t\u00e9l\u00e9chargement<\/a><\/p>\n<p>L&#8217;industrie 4.0 continue de transformer la fabrication en favorisant la num\u00e9risation, en am\u00e9liorant l&#8217;automatisation et en stimulant l&#8217;efficacit\u00e9. Gr\u00e2ce \u00e0 cette \u00e9volution, vous pouvez accomplir des t\u00e2ches plus rapidement, avec une plus grande pr\u00e9cision et moins d&#8217;erreurs. <\/p>\n<p>Dans cette derni\u00e8re version, nous sommes ravis d&#8217;apporter des am\u00e9liorations significatives en termes de performances. En fonction de votre \u00e9quipement, vous pouvez vous attendre \u00e0 une r\u00e9duction des temps de cycle, \u00e0 une acc\u00e9l\u00e9ration des calculs de planification des chemins d&#8217;inspection et \u00e0 une s\u00e9curit\u00e9 accrue lors de la cr\u00e9ation de trajectoires de MMT hors ligne. Et comme toujours, nous avons \u00e9largi la compatibilit\u00e9 avec de nouvelles interfaces pour rationaliser votre flux de travail.  <\/p>\n<p>D\u00e9couvrez les nouvelles fonctionnalit\u00e9s et les innovations de cette version ci-dessous !<\/p>\n<h4><strong><img decoding=\"async\" class=\"alignnone wp-image-19367216\" src=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-1-800x800.png\" alt=\"\" width=\"90\" height=\"90\" srcset=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-1-800x800.png 800w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-1-600x600.png 600w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-1-300x300.png 300w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-1-768x768.png 768w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-1-1536x1536.png 1536w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-1.png 1920w\" sizes=\"(max-width: 90px) 100vw, 90px\" \/><br \/>\nFonctions globales pour tous les segments<\/strong><\/h4>\n<p> <strong><img decoding=\"async\" class=\"alignnone wp-image-19367217\" src=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/icon-report-core-96.jpg\" alt=\"\" width=\"46\" height=\"46\"> Rapport d&#8217;inspection du premier article (FAI)<br \/>\n<\/strong>Nous comprenons les d\u00e9fis que repr\u00e9sente la validation de processus de production nouveaux ou mis \u00e0 jour dans des industries soumises \u00e0 des r\u00e9glementations et des contr\u00f4les de processus exigeants, afin de s&#8217;assurer que les pi\u00e8ces r\u00e9pondent aux exigences sp\u00e9cifi\u00e9es. C&#8217;est pourquoi nous avons simplifi\u00e9 le processus dans Metrolog X4. Il est d\u00e9sormais plus facile que jamais d&#8217;inclure un tableau FAI (First Article Inspection) dans vos rapports de m\u00e9trologie.  <\/p>\n<p> <strong><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-19367218\" src=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/icon-Scan-GDT-core-96.jpg\" alt=\"\" width=\"46\" height=\"46\"> Interface am\u00e9lior\u00e9e pour la commande &#8220;Scan GDT&#8221;<br \/>\n<\/strong>La commande &#8220;Scan PMI&#8221; a \u00e9t\u00e9 remplac\u00e9e par &#8220;Scan GD&amp;T&#8221; afin d&#8217;offrir une approche plus compl\u00e8te de l&#8217;affichage des attributs GD&amp;T suppl\u00e9mentaires pour chaque caract\u00e9ristique. Cette mise \u00e0 jour permet une compr\u00e9hension plus claire et plus intuitive de la pi\u00e8ce, dans une seule fen\u00eatre. <\/p>\n<p> <strong><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-19367219\" src=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/icon-geometric-tolerance-96-1.jpg\" alt=\"\" width=\"46\" height=\"46\"> Datum Reference Frame maintenant dig\u00e9rable \u00e0 partir de CAD<br \/>\n<\/strong>Nous continuons le travail d&#8217;int\u00e9gration de la prise en charge du Data Reference Frame (DRF) dans X4. Il est d\u00e9sormais possible d&#8217;importer et de d\u00e9coder automatiquement le DRF \u00e0 partir de la CAO. <\/p>\n<p> <strong><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-19367207\" src=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/icon-Point-Cloud-Alignment-core-96.jpg\" alt=\"\" width=\"44\" height=\"44\"> Mode &#8220;Courbes&#8221; pour l&#8217;alignement des nuages de<\/strong>points <strong><br \/>\n Les syst\u00e8mes de vision peuvent g\u00e9n\u00e9rer des nuages de points courbes, caract\u00e9ris\u00e9s par des points concentr\u00e9s le long des bords de la pi\u00e8ce num\u00e9ris\u00e9e. Pour rationaliser l&#8217;alignement de ces nuages de points avec votre fichier CAO, nous avons introduit un mode &#8220;Courbes&#8221; sp\u00e9cialis\u00e9, con\u00e7u pour compl\u00e9ter notre mode &#8220;Surface&#8221; existant. Cette am\u00e9lioration rend l&#8217;alignement optimal des nuages de points plus intuitif et plus efficace pour les nuages de points courbes.<\/strong>  <\/p>\n<hr>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-19367208\" src=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-Core-2.png\" alt=\"\" width=\"129\" height=\"81\" srcset=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-Core-2.png 800w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-Core-2-600x375.png 600w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-Core-2-400x250.png 400w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-Core-2-768x480.png 768w\" sizes=\"(max-width: 129px) 100vw, 129px\" \/><\/p>\n<p><b><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-19367209\" src=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/icon-collision-detection-96-1.jpg\" alt=\"\" width=\"44\" height=\"44\">  La d\u00e9tection et l&#8217;\u00e9vitement des collisions sont d\u00e9sormais disponibles dans Metrolog !<br \/>\n<\/b>Metrolog int\u00e8gre d\u00e9sormais des fonctions de d\u00e9tection et d&#8217;\u00e9vitement des collisions lorsqu&#8217;il est d\u00e9connect\u00e9 de la machine, ce qui garantit un fonctionnement plus s\u00fbr. La possibilit\u00e9 de mettre \u00e0 jour les trajectoires de mesure hors ligne tout en d\u00e9tectant et en \u00e9vitant les collisions potentielles est un garde-fou qui contribue \u00e0 prot\u00e9ger votre \u00e9quipement et \u00e0 am\u00e9liorer la s\u00e9curit\u00e9 g\u00e9n\u00e9rale. <\/p>\n<p> <strong><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-19367210\" src=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/icon-5-axes-96.jpg\" alt=\"\" width=\"44\" height=\"44\"> R\u00e9duction des temps de cycle pour le balayage 5 axes pour Revo<br \/>\n<\/strong>Pour optimiser l&#8217;efficacit\u00e9 pendant l&#8217;ex\u00e9cution du programme de balayage, nous avons introduit la possibilit\u00e9 d&#8217;encha\u00eener les balayages. Cette am\u00e9lioration permet d&#8217;effectuer plusieurs mesures cons\u00e9cutives sans avoir \u00e0 soulever la sonde. En maintenant un contact continu avec le mat\u00e9riau, il n&#8217;est plus n\u00e9cessaire de se r\u00e9tracter et de s&#8217;approcher \u00e0 nouveau. Cela am\u00e9liore le flux de travail et, plus important encore, r\u00e9duit la dur\u00e9e du cycle.   <\/p>\n<p> <b><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-19367211\" src=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/icon-new-interfaces-96.jpg\" alt=\"\" width=\"44\" height=\"44\"> Nouvelles interfaces disponibles<br \/>\n<\/b>Comme toujours, nous continuons d&#8217;assurer notre universalit\u00e9 en ajoutant deux nouvelles interfaces \u00e0 notre liste d&#8217;\u00e9quipements :<\/p>\n<ul>\n<li>Sur le contr\u00f4leur Hexagon, Metrolog supporte d\u00e9sormais les palpeurs Hexagon HH-A-H2.5.<\/li>\n<li>Support pour la s\u00e9rie Quantum X FaroArm de FARO<\/li>\n<\/ul>\n<hr>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-19367212\" src=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-i-Robot-2.png\" alt=\"\" width=\"130\" height=\"81\" srcset=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-i-Robot-2.png 800w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-i-Robot-2-600x375.png 600w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-i-Robot-2-400x250.png 400w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-i-Robot-2-768x480.png 768w\" sizes=\"(max-width: 130px) 100vw, 130px\" \/><\/p>\n<p> <strong><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-19367213\" src=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/icon-robot-ipp-96-1.jpg\" alt=\"\" width=\"44\" height=\"44\"> Mises \u00e0 jour des performances<br \/>\n<\/strong>Les temps de calcul pour la planification du chemin d&#8217;inspection (scanner lin\u00e9aire et radar laser) viennent d&#8217;\u00eatre acc\u00e9l\u00e9r\u00e9s.<br \/>\nVous recherchez un cobot sp\u00e9cifique ? Il est d\u00e9sormais possible de filtrer les &#8220;cobots&#8221; dans la fonctionnalit\u00e9 de recherche de la vue du catalogue. <\/p>\n<hr>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-19367214\" src=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-i-Tech-1.png\" alt=\"\" width=\"130\" height=\"81\" srcset=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-i-Tech-1.png 800w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-i-Tech-1-600x375.png 600w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-i-Tech-1-400x250.png 400w, https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/picto-totem-X4-i-Tech-1-768x480.png 768w\" sizes=\"(max-width: 130px) 100vw, 130px\" \/><\/p>\n<p> <strong><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-19367215\" src=\"https:\/\/www.metrologicdcs.com\/wp-content\/uploads\/icon-confocal-sensors-96.jpg\" alt=\"\" width=\"44\" height=\"44\"> Ajout de capteurs confocaux en ligne<br \/>\n<\/strong>Afin d&#8217;offrir plus de choix pour permettre l&#8217;automatisation de la m\u00e9trologie en ligne, nous avons ajout\u00e9 deux nouveaux capteurs confocaux :<\/p>\n<ul>\n<li>LMI Gocator 5512<\/li>\n<li>Precitec CLS2Pro<\/li>\n<\/ul>\n<hr>\n<p><strong>&#8230;Ce n&#8217;est pas tout<\/strong>, jetez un coup d&#8217;\u0153il \u00e0 toutes les nouvelles fonctionnalit\u00e9s en consultant les <a href=\"\/Products\/X4-Software\/Releases-Notes\/cid\/512\/V22GA\" target=\"_blank\" rel=\"noopener\" data-cke-saved-href=\"\/Products\/X4-Software\/Releases-Notes\/cid\/512\/V22GA\">notes de version.<\/a><\/p>\n<p><b>Une question sur la version ?<\/b><br \/>\nVeuillez contacter votre hotline sur nos <a href=\"https:\/\/extranet.metrologic.group\/en\/Support\/Service-Desk\/\" data-cke-saved-href=\"https:\/\/extranet.metrologic.group\/en\/Support\/Service-Desk\/\" data-cke-saved- rel=\"nofollow noopener\" target=\"_blank\">portails de support technique <\/a> ou votre <a href=\"https:\/\/www.metrologicgroup.com\/contact\/\" target=\"_blank\" rel=\"noopener nofollow\" data-cke-saved-href=\"https:\/\/www.metrologicgroup.com\/contact\/\" data-cke-saved->revendeur local<\/a>.<br \/>\nVotre <a href=\"https:\/\/www.metrologicgroup.com\/contact\/\" target=\"_blank\" rel=\"noopener nofollow\" data-cke-saved-href=\"https:\/\/www.metrologicgroup.com\/contact\/\" data-cke-saved->repr\u00e9sentant Metrologic<\/a> local est \u00e9galement disponible pour vous offrir toute formation sur site dont vous pourriez avoir besoin et qui pourrait vous aider \u00e0 mieux b\u00e9n\u00e9ficier de tous les nouveaux outils et fonctionnalit\u00e9s mis \u00e0 disposition dans les deux derni\u00e8res versions majeures de la ligne de produits X4.<\/p>\n<p>Merci de votre attention !<br \/>\nL&#8217;\u00e9quipe de Metrologic Group<\/p>\n","protected":false},"excerpt":{"rendered":"<p>La nouvelle version de notre famille de solutions X4 est disponible pour vos solutions logicielles Metrolog et Silma&#8230;<\/p>\n","protected":false},"author":2,"featured_media":19376220,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":"","_members_access_role":[],"_members_access_error":""},"categories":[156,27],"tags":[511,34,505,35,847],"expertise":[],"industry":[],"langue-parlee":[],"class_list":["post-19374671","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-article-dexpert","category-news-fr","tag-liberation","tag-metrolog-fr","tag-nouvelle-version-fr","tag-silma-fr","tag-v22-fr"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.metrologicdcs.com\/fr\/wp-json\/wp\/v2\/posts\/19374671","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.metrologicdcs.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.metrologicdcs.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.metrologicdcs.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.metrologicdcs.com\/fr\/wp-json\/wp\/v2\/comments?post=19374671"}],"version-history":[{"count":0,"href":"https:\/\/www.metrologicdcs.com\/fr\/wp-json\/wp\/v2\/posts\/19374671\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.metrologicdcs.com\/fr\/wp-json\/wp\/v2\/media\/19376220"}],"wp:attachment":[{"href":"https:\/\/www.metrologicdcs.com\/fr\/wp-json\/wp\/v2\/media?parent=19374671"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.metrologicdcs.com\/fr\/wp-json\/wp\/v2\/categories?post=19374671"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.metrologicdcs.com\/fr\/wp-json\/wp\/v2\/tags?post=19374671"},{"taxonomy":"expertise","embeddable":true,"href":"https:\/\/www.metrologicdcs.com\/fr\/wp-json\/wp\/v2\/expertise?post=19374671"},{"taxonomy":"industry","embeddable":true,"href":"https:\/\/www.metrologicdcs.com\/fr\/wp-json\/wp\/v2\/industry?post=19374671"},{"taxonomy":"langue-parlee","embeddable":true,"href":"https:\/\/www.metrologicdcs.com\/fr\/wp-json\/wp\/v2\/langue-parlee?post=19374671"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}